L68B2 Mast Section What are the reasons for the variation of the tower's amplitude

29-10-2019

In the operation of the tower crane, there are often faults with different amplitude of the tower crane, and why these failures occur. The following reasons are summarized:
1. Causes of failure: Damage to gear or bearings of the reducer
Solution: replacement
2. Cause of failure: Reduction engine lacks oil
Solution: Identify causes, overhaul and refuel
3. Cause of failure: Steel rope is too tight
Solution: Adjusting the tightness of the wire rope
4. Causes of failure: Wear of elastic sleeve of coupling
Solution: Replacement
5. Fault Causes: Motor Fault
Solution: Find Electrical Fault
6. Causes of failure: Broken roller bearings or pulleys
Solution: Replacement of bearings

L68B2 Mast Section  

L68B2 mast section the specification can suitable this situaton no problem .